Mas-Hamilton
Auditcon 2100 |
| check time on lock |
change daylight saving status |
set / change date & time |
| |
| To Check Time on Lock. |
- 1. Power up lock by turning dial
- 2. Press "#" "7"
|
- Lock will show current Daylight Savings time status.
"ds" followed by either "off" or "on"
- Then lock will flash time currently set on lock "cl"
followed by "HH - MM - SS"
- This will be followed by Europeaon Date status. "Ed"
followed by either "off" or "on" (european date format is date / month
/ year)
- Lock will then show current date set "MM-DD-YY"
|
| 3. When Done press
"#" |
| |
| To Change Daylight Saving Time Status |
| 1. Power up Lock by
turning dial |
| 2. Press "#"
"8" |
- Lock will show ESP (enter
supervisor password)
|
| 3. Enter 6-digit
supervisor password |
- Lock will show ISI (insert supervisor
identifier)
|
| 4. Touch Supervisor
key (Black s, or ss,) to lock |
- Lock will show ESS (enter supervisor
submenu)
|
| 5. Press
"2" |
- Lock will flash current status of Daylight Savings
Time"dS" "on" or "off"
|
| 6. To switch status,
press the "*" |
- Lock will go blank, DST status has been changed
|
| |
| To Set / Change the Time & Date |
| 1. Power up Lock by turning
dial |
| 2. Press
"#" "8" |
- Lock will show ESP (enter supervisor
password)
|
| 3. Enter 6-digit
supervisor password |
- Lock will show ISI (insert supervisor
identifier)
|
| 4. Touch Supervisor
key (Black S, or SS,) to lock |
- Lock will Show ESS (enter supervisor
submenu)
|
| 5. Press
"1" |
- Lock will show ECL (enter clock time)
|
| 6. Using military
time, enter the Hour, Minute, Second, "HH - MM - SS" |
- Lock will show status of daylight savings time -
"dS" + "on" or "off"
- Lock will then flash the time you setting -
"CL" followed by "HH-MM-SS"
|
| 7. If time is
correct, press "#", If time is incorrect press "*" then start again at
step 6 |
- Lock will then show EdA (enter date)
|
| 8. Enter the date as
"MM - DD - YY" |
- Lock will then flash the status of the europeaon date format -
"Ed" "off" or "on"
- Lock will then flash the date you are setting - "dA"
followed by "MM-DD-YY"
|
| 9. If date is correct, press
"#", If date is incorrect press "*"
then start again at step 8 |
| |
E-Mail us any questions or comments
you may have |
- L. I. LOCKSMITH & ALARM CO., INC.
- "Your Security Technology Company"
- 26 WEST OLD COUNTRY ROAD - HICKSVILLE NY 11801 (516)
931-2273 Fax: (516) 931-7334 www.lilocksmith.com
|